====== 3-phase currents ====== All currents in FEEM are peak, so for RMS the values have to be scaled accordingly. In order to set up a 3-phase system of currents, with the same value of **1 A peak** for each phase, and phase angles as indicated, the following strings should be entered in the appropriate current definition in FEMM magnetic model, with ''I'' denoting the imaginary number (I2 = -1): I1 (at 0°) = ''1'' I2 (at +120°) = ''-0.5 + I * 0.866'' I3 (at -120°) = ''-0.5 - I * 0.866'' In order to use different amplitudes, these can be just multiplied by the required constant. For example, in order to achieve a current of **10 A rms** in each phase (with the same angles), the values should be multiplied by 10 * 1.4142 = 14.142 (so that the sqrt(2) scaling is also applied). Hence: I1 (at 0°) = ''14.142'' I2 (at +120°) = ''-7.0711 + I * 12.2474'' I3 (at -120°) = ''-7.0711 - I * 12.2474'' Note that you can multiply directly inside the input box, because the value will be evaluated correctly. So for example, typing in: \\ ''-0.5 * 14.142 - I * 0.866 * 14.142'' will set it to ''-7.0711 - I * 12.2474''. {{3phase_current.png}} Setting up the complex value of I2 {{page>insert/paypal}}